ECM

Engine Control and Monitoring

BB100


The BB100 blow-by meter has all of the features of the BB400MR except that the BB100 is a single-range meter measuring from 4 to 150 liters/min (LPM). This range is suitable for blow-by measurement of most passenger car and light-duty truck engines.

Range: 4 to 150 liters/min (LPM), 0.15 to 5.4 ft3/min (CFM)
Accuracy: 1% of reading or 1 LPM
Pressure Drop: 0.5" H2O at 20% of maximum flow
Temperature Range: 0 to 250 deg C (flow), -20 to 85 deg C (electronics)
Analog Output: 0 to 5 V, programmable for flowrate or total flow, range, and averaging
RS-232: Bidirectional. Software included.
Material Exposed to Blow-by: Anodized aluminum, Stainless steel, Teflon
Power: 11 to 28 VDC, AC/DC adapter supplied
Size: 4" x 14.5" x 5.25", 102 mm x 368 mm x 133 mm (W x H x D)
Weight: 5.5 lbs., 2.5 kg.